Skip to content
For the complete documentation index, see llms.txt. This page is also available as Markdown.

Add-RASProviderRemotePCStatic

SYNOPSIS

Adds a Remote PC Static to a Provider.

SYNTAX

Add-RASProviderRemotePCStatic [-Id] <uint> -RemotePCStaticName <string> [-MAC <string>]
 [-Subnet <string>] [<CommonParameters>]
Add-RASProviderRemotePCStatic [-InputObject] <RemotePCStaticProvider> -RemotePCStaticName <string>
 [-MAC <string>] [-Subnet <string>] [<CommonParameters>]
Add-RASProviderRemotePCStatic [-Server] <string> [[-SiteId] <uint>] -RemotePCStaticName <string>
 [-MAC <string>] [-Subnet <string>] [<CommonParameters>]

DESCRIPTION

Adds a Remote PC Static to a Provider.

EXAMPLES

Example 1

Add-RASProviderRemotePCStatic -Id 1 -RemotePCStaticName Test0 -MAC 00-11-22-33-44-00

Adds a Remote PC Static Test0 to the Remote PC Static List of the Provider with Id 1.

PARAMETERS

-RemotePCStaticName

Remote PC Static Name.

-MAC

Remote PC Static MAC Address.

-Subnet

Remote PC Static Subnet. Default: 0.0.0.0

-Server

The name of the target Provider server.

This must be the actual server name used in the RAS farm.

-SiteId

Site ID in which to modify the specified Provider server.

If the parameter is omitted, the site ID of the Licensing Server will be used.

-Id

The ID of the Provider server to modify. To obtain the ID, use the Get-RASProvider cmdlet.

-InputObject

An object representing the Provider server to modify.

To obtain the object, use the Get-RASProvider cmdlet.

Type reference: RemotePCStaticProvider

CommonParameters

This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.

INPUTS

RemotePCStaticProvider

OUTPUTS

None

Last updated