Set-RASMFARadiusAuto

NAME

Set-RASMFARadiusAuto

SYNOPSIS

Modifies automation settings to Radius provider settings based on Id.

SYNTAX

Set-RASMFARadiusAuto [Id]** (uint) [RadiusAutoId] (uint) [ActionMessage (string)] [AutoSend (bool)] [Command (string)] [Description (string)] [Enabled (bool)] [-Image {Alert | Message | Email | Call | Chat | Flag}] [NewTitle (string)] [-Priority {Up | Down}] [(CommonParameters)]

Set-RASMFARadiusAuto [-InputObject] (MFA) [ActionMessage (string)] [AutoSend (bool)] [Command (string)] [Description (string)] [Enabled (bool)] [-Image {Alert | Message | Email | Call | Chat | Flag}] [NewTitle (string)] [-Priority {Up | Down}] [(CommonParameters)]

Set-RASMFARadiusAuto [Name]** (string) [[-SiteId] (uint)] [ActionMessage (string)] [AutoSend (bool)] [Command (string)] [Description (string)] [Enabled (bool)] [-Image {Alert | Message | Email | Call | Chat | Flag}] [NewTitle (string)] [-Priority {Up | Down}] [(CommonParameters)]

DESCRIPTION

Modifies automation settings to Radius provider settings based on Id.

PARAMETERS

RadiusAutoId (uint)

The ID of Radius Auto to modify.

AutoSend (bool)

Whether the RADIUS Automation autoSend is enabled or not

Command (string)

RADIUS Automation command

Enabled (bool)

Whether the RADIUS Automation is enabled/disabled

Image (ImageType)

RADIUS Automation image

Possible values: Alert, Message, Email, Call, Chat, Flag

Description (string)

RADIUS Automation description

ActionMessage (string)

RADIUS Automation action message

NewTitle (string)

RADIUS Automation title

Priority (MoveDirection)

The direction to move the Radius Automation : Up or Down (changes the priority of the Radius Automation accordingly)

Possible values: Up, Down

Name (string)

The name of the target multi-factor authentication .

This must be the actual multi-factor authentication name used in the RAS farm.

SiteId (uint)

Site ID in which to modify the specified multi-factor authentication .

If the parameter is omitted, the site ID of the Licensing Server will be used.

Id (uint)

The ID of the multi-factor authentication to modify. To obtain the ID, use the Get-RASMFA cmdlet.

InputObject (MFA)

The multi factor authentication to modify.

To obtain an object of type MFA, use the Get-RASMFA cmdlet.

(CommonParameters)

INPUTS

MFA

OUTPUTS

-none-

EXAMPLES

---------- EXAMPLE 1 ----------

Set-RASMFARadiusAuto -Id 2 -Command Test -NewTitle Test

Modifies entry of the Radius automation item at ID 2 with new Command and Title.

Last updated