Set-RASMFARadiusAuto

NAME

Set-RASMFARadiusAuto

SYNOPSIS

Modifies automation settings to Radius provider settings based on Id.

SYNTAX

Set-RASMFARadiusAuto [-Id] <uint> [-RadiusAutoId] <uint> [-ActionMessage <string>] [-AutoSend <bool>] [-Command <string>] [-Description <string>] [-Enabled <bool>] [-Image {Alert | Message | Email | Call | Chat | Flag}] [-NewTitle <string>] [-Priority {Up | Down}] [<CommonParameters>] Set-RASMFARadiusAuto [-InputObject] <MFA> [-ActionMessage <string>] [-AutoSend <bool>] [-Command <string>] [-Description <string>] [-Enabled <bool>] [-Image {Alert | Message | Email | Call | Chat | Flag}] [-NewTitle <string>] [-Priority {Up | Down}] [<CommonParameters>] Set-RASMFARadiusAuto [-Name] <string> [[-SiteId] <uint>] [-ActionMessage <string>] [-AutoSend <bool>] [-Command <string>] [-Description <string>] [-Enabled <bool>] [-Image {Alert | Message | Email | Call | Chat | Flag}] [-NewTitle <string>] [-Priority {Up | Down}] [<CommonParameters>]

DESCRIPTION

Modifies automation settings to Radius provider settings based on Id.

PARAMETERS

-RadiusAutoId <uint> The ID of Radius Auto to modify.

        Required?                    true
        Position?                    0
        Default value                0
        Accept pipeline input?       false
        Accept wildcard characters?  false

-AutoSend <bool> Whether the RADIUS Automation autoSend is enabled or not

        Required?                    false
        Position?                    named
        Default value                
        Accept pipeline input?       false
        Accept wildcard characters?  false

-Command <string> RADIUS Automation command

        Required?                    false
        Position?                    named
        Default value                
        Accept pipeline input?       false
        Accept wildcard characters?  false

-Enabled <bool> Whether the RADIUS Automation is enabled/disabled

        Required?                    false
        Position?                    named
        Default value                True
        Accept pipeline input?       false
        Accept wildcard characters?  false

-Image <ImageType> RADIUS Automation image Possible values: Alert, Message, Email, Call, Chat, Flag

        Required?                    false
        Position?                    named
        Default value                
        Accept pipeline input?       false
        Accept wildcard characters?  false

-Description <string> RADIUS Automation description

        Required?                    false
        Position?                    named
        Default value                
        Accept pipeline input?       false
        Accept wildcard characters?  false

-ActionMessage <string> RADIUS Automation action message

        Required?                    false
        Position?                    named
        Default value                
        Accept pipeline input?       false
        Accept wildcard characters?  false

-NewTitle <string> RADIUS Automation title

        Required?                    false
        Position?                    named
        Default value                
        Accept pipeline input?       false
        Accept wildcard characters?  false

-Priority <MoveDirection> The direction to move the Radius Automation : Up or Down (changes the priority of the Radius Automation accordingly) Possible values: Up, Down

        Required?                    false
        Position?                    named
        Default value                
        Accept pipeline input?       false
        Accept wildcard characters?  false

-Name <string> The name of the target multi-factor authentication . This must be the actual multi-factor authentication name used in the RAS farm.

        Required?                    true
        Position?                    0
        Default value                
        Accept pipeline input?       false
        Accept wildcard characters?  false

-SiteId <uint> Site ID in which to modify the specified multi-factor authentication . If the parameter is omitted, the site ID of the Licensing Server will be used.

        Required?                    false
        Position?                    1
        Default value                0
        Accept pipeline input?       false
        Accept wildcard characters?  false

-Id <uint> The ID of the multi-factor authentication to modify. To obtain the ID, use the Get-RASMFA cmdlet.

        Required?                    true
        Position?                    0
        Default value                0
        Accept pipeline input?       false
        Accept wildcard characters?  false

-InputObject <MFA> The multi factor authentication to modify. To obtain an object of type MFA, use the Get-RASMFA cmdlet.

        Required?                    true
        Position?                    0
        Default value                
        Accept pipeline input?       true (ByValue)
        Accept wildcard characters?  false

<CommonParameters>

        This cmdlet supports the common parameters: Verbose, Debug,
        ErrorAction, ErrorVariable, WarningAction, WarningVariable,
        OutBuffer, PipelineVariable, and OutVariable. For more information, see 
        about_CommonParameters . 

INPUTS

MFA

OUTPUTS

-none-

EXAMPLES

---------- EXAMPLE 1 ---------- Set-RASMFARadiusAuto -Id 2 -Command Test -Title Test Modifies entry of the Radius automation item at ID 2 with new Command and Title.

Last updated

© 2024 Parallels International GmbH. All rights reserved.